Pentanediol for Gaussian using Nanocad & CSD
Login to SEAGrid desktop client.
Select Nanocad editor
Image I - Desktop client home. Select NanocadAfter NanoCAD has launched, take your time to read the text "Summary of NanoCAD Commands" at the top of NanoCAD window (Indicated by the green box in Image I).
You will get the basic idea how to use NanoCAD.
Click 'Clear' to remove the existing water molecule.
Click 'Structure'.
Image II - Nanocad editor, clear the water molecule
From 'Import Structure' click Database and then select CSD.
Image III - Select CSD to search for a new moleculeSearch for ‘pentanediol’ (This would take about 20 seconds). From the list given, double-click on the second one ‘anti-2,4-Diphenylpentane-2,4-diol’.
Image IV - Pentanediol search results in CSD searchThe complex will get ported into the Nanocad editor. Break the C bond between the highlighted atoms. Then select ‘Group’ and do ctrl+alt+click on the C atom (Highlighted in the image) of Phenyl. Then once the group is highlighted, click ‘Clear’ and remove the phenyl molecule.
Image V - anti-2,4-Diphenylpentane-2,4-diol complex in Nanocad editorSimilar to above remove the bind between the highlighted Cs and then remove the highlighted phenyl molecule similar to above.
Image VI - anti-2,4-Diphenylpentane-2,4-diol complex with removed atomsCtrl+click on the gray background area to center the molecule. You can rotate the molecule by click and drag.
Image VII - Pentanediol acidClick 'Add H' button – on the lower righthand corner.
Image VII - Add H to the moleculeImport the molecule as a Gaussian input
Image VIII - Importing as Gaussian inputRead and say OK, to the confirmation and warning message.
Image IX - Confirmation and warning messages on exporting molecule.Above input file is then exported into Gaussian Editor GUI. Add the Methods and Wavefunction.
Image X - Add Method B3LYP & WavefunctionAdd Basis set
Image XI - Add Basis setAdd Job Type
Image XII - Add Job typeAdd Keywords, 'Common Keywords' → Pop and from the pop-up window select 'Reg' and click 'Done'. From 'Other Keywords' select GFInput, GFPrint and IOp. From IOp window add Overly=6, Option=7 and Value=3 click 'Done' on both windows.
Image XIII - Adding Keywords to the Gaussian inputIn Gaussian GUI add
%nproc - 16
%mem - 3000
Checkpoint File - Pentane23diol
Check Use #P
Add job title and Description - Pentane23diol #P RB3LYP/cc-pVDZ Pop=(Reg) GFInput GFPrint Iop(6/7=3) Opt Freq
Charge - 0
Multiplicity - 1
Now 'Done & Export'.
Image XIV - Final configurations in Gaussian GUIIn the Create Experiment window
Provide an experiment name
Select comet.sdsc.edu to run the job
Choose 'Shared' queue
Submit