Pentanediol for Gaussian using Nanocad & CSD
Pentanediol for Gaussian using Nanocad & CSD
- Login to SEAGrid desktop client.
- Select Nanocad editor
Image I - Desktop client home. Select Nanocad - After NanoCAD has launched, take your time to read the text "Summary of NanoCAD Commands" at the top of NanoCAD window (Indicated by the green box in Image I).
- You will get the basic idea how to use NanoCAD.
- Click 'Clear' to remove the existing water molecule.
- Click 'Structure'.
Image II - Nanocad editor, clear the water molecule
- From 'Import Structure' click Database and then select CSD.
Image III - Select CSD to search for a new molecule - Search for ‘pentanediol’ (This would take about 20 seconds). From the list given, double-click on the second one ‘anti-2,4-Diphenylpentane-2,4-diol’.
Image IV - Pentanediol search results in CSD search - The complex will get ported into the Nanocad editor. Break the C bond between the highlighted atoms. Then select ‘Group’ and do ctrl+alt+click on the C atom (Highlighted in the image) of Phenyl. Then once the group is highlighted, click ‘Clear’ and remove the phenyl molecule.
Image V - anti-2,4-Diphenylpentane-2,4-diol complex in Nanocad editor - Similar to above remove the bind between the highlighted Cs and then remove the highlighted phenyl molecule similar to above.
Image VI - anti-2,4-Diphenylpentane-2,4-diol complex with removed atoms - Ctrl+click on the gray background area to center the molecule. You can rotate the molecule by click and drag.
Image VII - Pentanediol acid - Click 'Add H' button – on the lower righthand corner.
Image VII - Add H to the molecule - Import the molecule as a Gaussian input
Image VIII - Importing as Gaussian input - Read and say OK, to the confirmation and warning message.
Image IX - Confirmation and warning messages on exporting molecule. Above input file is then exported into Gaussian Editor GUI. Add the Methods and Wavefunction.
Image X - Add Method B3LYP & Wavefunction- Add Basis set
Image XI - Add Basis set - Add Job Type
Image XII - Add Job type - Add Keywords, 'Common Keywords' → Pop and from the pop-up window select 'Reg' and click 'Done'. From 'Other Keywords' select GFInput, GFPrint and IOp. From IOp window add Overly=6, Option=7 and Value=3 click 'Done' on both windows.
Image XIII - Adding Keywords to the Gaussian input - In Gaussian GUI add
- %nproc - 16
- %mem - 3000
- Checkpoint File - Pentane23diol
- Check Use #P
- Add job title and Description - Pentane23diol #P RB3LYP/cc-pVDZ Pop=(Reg) GFInput GFPrint Iop(6/7=3) Opt Freq
- Charge - 0
- Multiplicity - 1
- Now 'Done & Export'.
Image XIV - Final configurations in Gaussian GUI - In the Create Experiment window
- Provide an experiment name
- Select comet.sdsc.edu to run the job
- Choose 'Shared' queue
- Submit
, multiple selections available,
Related content
Building a Molecule (Acetaldehyde) & Running Gaussian Job
Building a Molecule (Acetaldehyde) & Running Gaussian Job
More like this
Using Nanocad
Using Nanocad
More like this
Using Nanocad to find Molecules
Using Nanocad to find Molecules
More like this
Using Gamess Editor
Using Gamess Editor
More like this
Using Jamberoo
Using Jamberoo
More like this
Use Jamberoo Editor and build Gamess input
Use Jamberoo Editor and build Gamess input
More like this